Air Quality Meter PCE-EM 880
- HCHO measuring range: 0.00-5.00 mg/m³
- TVOC measuring range: 0.00-9.99 mg/m³
- Temperature measuring range: 0-50 °C / 32-122 °F
- Humidity measuring range: 0-100% RH
- Memory for 5000 measuring points
The Air Quality Meter PCE-EM 880 is equipped with sensors to measure HCHO, TVOC, ambient temperature, and humidity, covering a broad range of air quality parameters. The TVOC measurement range spans from 0.00 to 9.99 mg/m³, with an accuracy of ±5% for both HCHO and TVOC measurements, making it an ideal tool for indicative air quality assessments.
Powered by a built-in 1500 mAh battery, the air quality meter can be used as a mobile device. Once the battery is depleted, it can be recharged via the micro USB interface with a 5 V DC power supply.
This air quality meter is commonly used to monitor air quality in offices, workshops, schools, and logistics facilities, particularly for detecting volatile organic compounds and formaldehyde.
The device stores readings internally, with a memory capacity of 5000 measurement points. Users can analyze the data directly on the meter. Additionally, readings can be transferred to a PC, where the meter is recognized as a mass storage device, allowing for cross-platform compatibility. The measurements are saved in CSV file format, ensuring easy data management.
HCHO | |
Measuring range | 0.00 … 5.00 mg/m³ |
Resolution | 0.01 mg/m³ |
Accuracy | ±5 % of measuring range |
TVOC | |
Measuring range | 0.00 … 9.99 mg/m³ |
Resolution | 0.01 mg/m³ |
Accuracy | ±5 % of measuring range |
Temperature | |
Measuring range | 0 … 50 °C / 32 … 122 °F |
Resolution | 0.1 °C / 0.1 °F |
Accuracy | ±2 °C / ±4 °F |
Humidity | |
Measuring range | 0 … 100 % RH |
Resolution | 0.1 % RH |
Accuracy | ±3.5 % at (20 … 80 % RH) |
±5 % at (0 … 20 %) | |
±5 % at (80 … 100 %) | |
Further specifications | |
Memory space | for 5000 measuring points |
File format | CSV |
Memory rate | 1 minute, 15 minutes, 1 hour |
Warm-up time | HCHO: 10 seconds |
TVOC: 90 seconds | |
Units | temperature: °C, °F |
HCHO / TVOC: ppm, mg/m3 | |
Measuring rate | 1 Hz |
Alarm | visual |
Interface | Micro USB interface |
Power supply (battery) | 3.7 V, 1500 mAh |
Power supply (power pack) | 5 V DC, 1 A |
Operating conditions | 0 … 45 °C / 32 … 113 °F, <90 % RH |
Storage conditions | -10 … 55 °C / 14 … 131 °F, <90 % RH |
Dimensions | 54 x 215 x 34 mm / 2.1 x 8.4 x 1.3″ |
Weight | 143 g / 5.0 oz |
1 x Air quality meter PCE-EM 880
1 x Micro USB cable
1 x Instruction manual